A 10-amp multi-stage battery charger with an enclosed terminal block

Designed to be hard wired into your electrical system, the TRUECHARGE 10TB is ideal for batteries from 25 amp-hours to 200 amp-hours. The multi-stage charge is microprocessor-controlled, ripple-free and faster charging than many 15, 20, and 30 amp rated Ferro resonant battery chargers.

The accurate delivery of the three-stage charge eliminates the risk of overcharged or boiled batteries. The ripple-free, filtered DC output helps prolong the life of batteries. TRUECHARGE 10TB is also able to recharge completely discharged batteries.

 



TRUECHARGE
10TB Safety
Features:

Over-temperature
shutdown

Overload protection

Ignition protection

Transformer isolated for safety and to protect against electrolysis

Reverse polarity protection

Short-circuit protection

Surge protection

Covered terminal block for safe and easy connection

 


TRUECHARGE 10TB Performance Features:


Fully Automatic Operation:
Charger can be left permanently attached to batteries for true "connect and forget" operation

Variable Battery Type Settings:
Adjust charger output for the different charging requirements of sealed (gel) lead-acid and conventional flooded (wet) batteries

CSA/NRTL approved to CSA and UL standards for marine battery chargers:
Includes ingnition protection

Battery Status LED indicators:
Display stage of charge and battery ready status

Covered Wiring Compartment:
Keeps wires bundled and provides access to external fuses and battery type selector switch

Compact Size and Light Weight:
Designed for easy installation


 

 

TRUECHARGE 10TB


 Electrical Performance  
 Output Current (bulk charge)  10 amps continuous duty
 Input Voltage Range  90 - 135 V AC, 50/60 Hz, 3A

 Output Voltage

Charge (flooded/gel)

Float (flooded/gel)

  (*Normal, Depending on Settings)

  14.2 - 14.4 V DC*

  13.5 - 13.8 V DC*

 Charger efficiency  approximately 82%
 Recommended battery type  flooded or gel
 Recommended battery size  12V lead-acid batteries, 25Ah to 200Ah
   
 Mechanical Specifications  
 AC and DC connection  6 position terminal block with No. 8 screw (for ring terminals with max. 0.42" OD)
 Battery connections  2 positive terminals, 1 common negative
 Weight  3.0 lbs./ 1.4 kg.
 Dimensions (LxWxH)  10.75" x 6.5" x 2.75" / 273 mm x 165 mm x 70 mm
   12V lead-acid batteries: 25 Ah to 200 Ah
 Operating Environment  
 Operating temperature  0û C to +40ûC
 Storage temperature  -25ûC to +70ûC
   
 Protection Specifications  
 Reverse polarity protection  15A fuse
 Short circuit protection  Yes (current limit)
 Over-temperature protection  Yes (shutdown)
   
 Standards Approval  CSA/NRTL approved to CSA 107.2, UL1236, including ignition protection and the  marine supplement

Battery charge times: (based on a recommended 50% discharge)

Battery Group Approx amp hours Charge time (hours)
U-1 30 2
24 75 5
27 100 6.5

Three-stage Charging

Multistage charging ensures batteries receive optimum charging throughout the charge cycle, but with minimal wear and tear. There are three stages of operation:

1. Bulk Charge: replenishes 70-80% of the battery's charge at the fastest possible rate.

2. Absorption: replenishes the remaining 20-30% of the charge, bringing the battery to full charge at a slow, safe rate.

3. Float: supplies a light current to keep the battery topped up.

Back to Chargers Page