Circuit Breakers |
General
Description |
Max
Poles |
Current &
Voltage Rating |
Max.
Interrupting
Capacity |
Approvals* |
View
Snapak®
details
 |
 |
Compact
magnetic protection |
 |
Patented snap
action mechanism increases operational life |
 |
Paddle, baton,
push pull, push-to-reset and rocker actuation in choice of colors |
 |
Illuminated
rocker handle with choice of colors and markings |
 |
Aesthetically
pleasing for front panel mounting |
|
 |
2 |
|
 |
0.10 to 7.5
amps at 50Vdc and 250Vac |
 |
0.10 to 30
amps at 32Vdc |
 |
0.10 to 30
amps at 120Vac |
 |
0.10 to 25
amps at 120/240Vac (two poles) |
 |
0.10 to 20
amps at 250Vac (50/60 Hz @ 500AIC) |
 |
0.10 to 20
amps at 65Vdc (two poles) 500AIC |
|
 |
1000 amps |
|
 |
UL Recognized |
 |
CSA Certified |
 |
VDE Approved |
 |
CE Compliant |
|
View
IPA
details
|
 |
Compact
magnetic protection |
 |
Quick-connect,
screw, PC board mount terminals available |
 |
Auxiliary
switch options |
 |
Multi-pole
versions with
multi or single handle |
|
 |
3 |
|
 |
0.05-30 amps,
65Vdc |
 |
0.05-20 amps,
80Vdc (300 AIC) |
 |
0.05-25 amps,
250Vac, 50/60Hz |
 |
25.1-30 amps,
240Vac, 50/60Hz |
 |
0.10-15 amps,
250Vac, 400Hz |
 |
0.05-25 amps,
65Vdc (TUV) |
 |
0.05-25 amps,
250Vac, 50/60Hz (TUV) |
 |
0.05-15 amps,
250Vac, 400Hz (TUV) |
|
 |
1000 amps |
|
 |
UL Recognized |
 |
CUL Recognized |
 |
TUV Certified |
 |
CE Compliant |
|
View
IAG/IUG/IEG/CEG
details

|
 |
IEG version
meets IEC spacing requirements for installation in equipment that
must comply with IEC 601 and 950, and VDE 0730, 0804, and 0805 |
 |
Multi-pole
versions, multi or single handle |
 |
Auxiliary
switch option |
 |
Snap-in
mounting option |
 |
Mid-trip
handle option |
 |
Dual frequency
option |
|
 |
6 |
|
 |
.050 - 50
amps, 80Vdc |
 |
.050 - 50
amps, 240Vac, 50/60 Hz |
 |
.050 - 30
amps, 277Vac, 50/60 Hz |
 |
.050 - 30
amps, 250Vac, 400 Hz |
|
 |
5000 amps,
240Vac, 50/60 Hz |
 |
1500 amps,
240Vac, 400 Hz |
 |
7500 amps,
80Vdc (IEG) |
 |
5000 amps,
80Vdc (CEG) |
 |
2000 amps,
250Vac, 50/60 Hz (VDE) |
 |
4000 amps,
80Vdc, (VDE) |
|
 |
UL 489A Listed
(CEG) |
 |
UL Recognized
|
 |
CSA Certified
|
 |
VDE Approved (IEG,
CEG) |
 |
UL 1500
Certified |
 |
CE Compliant |
|
View
IAL/IUL/IEL
details

|
 |
IEL versions
meet IEC spacing requirements for installation in equipment that
must comply with IEC 601 and 950, and VDE 0730, 0804, and 0805 |
 |
Multi-Pole
versions with multi or single handle |
 |
Auxiliary
switch option |
 |
Snap-in
mounting option |
 |
Mid-trip
handle option |
 |
Dual frequency
option |
|
 |
6 |
|
 |
.050 to 100
amps, 65Vdc |
 |
.050 to 70
amps, 80Vdc |
 |
.050 - 70
amps, 240Vac, 50/60 Hz |
 |
.050 - 50
amps, 277Vac, 50/60 Hz |
 |
.050 - 30
amps, 277/480Vac, 50/60 Hz |
 |
.050 - 50
amps, 250Vac, 400 Hz |
|
 |
5000 amps,
250Vac, 50/60 Hz |
 |
1500 amps,
250Vac, 400 Hz |
 |
7500 amps,
80Vdc |
 |
2000 amps,
240Vac, 50/60 Hz (VDE) |
 |
2000 amps,
415Vac, 50/60 Hz (VDE) |
 |
4000 amps,
80Vdc (VDE) |
 |
2000 amps,
277/480Vac |
|
 |
UL Recognized |
 |
CSA Certified
|
 |
VDE Approved (IEL) |
 |
UL 1500
Certified |
 |
CE Compliant |
|
View
LEL
details
 |
 |
LEL versions
meet IEC spacing requirements for installation in equipment that
must comply with IEC 601 and 950, and VDE 0730, 0804, and 0805 |
 |
Multi-pole
versions with multi or single handle |
 |
Auxiliary
switch option |
 |
Snap-in
mounting option |
 |
Mid-trip
handle option |
 |
Dual frequency
option |
|
 |
3 |
|
 |
.050 to 100
amps, 80Vdc |
 |
.050 to 50
amps, 125Vac, 50/60 Hz |
 |
..050 - 70
amps, 120/240Vac 50/60Hz |
 |
.100 - 100
amps, 80Vdc (VDE) |
 |
.100 - 50
amps, 250Vac (VDE) |
|
 |
50000 amps,
80Vdc |
 |
5000 amps,
125Vac, 120/240Vac, 50/60 Hz |
 |
2000 amps,
80Vdc (VDE) |
 |
2000 amps,
240Vac, 50/60 Hz (VDE) |
|
 |
UL 489 Listed |
 |
CSA Certified
|
 |
VDE Approved |
 |
CE Compliant |
|
View
LELHP
details
|
 |
Unique,
parallel current sensing design |
 |
Compact size,
high current capacity |
 |
Auxiliary
switch options available |
 |
Mid-trip
handle option |
|
 |
1 |
|
 |
125 amps,
80Vdc, paralleled poles |
 |
150 amps,
80Vdc, paralleled poles |
 |
175 amps,
80Vdc, paralleled poles |
 |
200 amps,
80Vdc, paralleled poles |
|
 |
50000 amps,
80Vdc
(up to 100 amps) |
 |
50000 amps,
65Vdc
(up to 200 amps) |
 |
10000 amps,
80Vdc
(>100 amps) |
|
 |
UL 489A Listed |
 |
CSA Certified
|
|
View
IALR/IULR/IELR
details

|
 |
IELR versions
meet IEC spacing requirements for installation in equipment that
must comply with IEC 601 and 950, and VDE 0730, 0804, and 0805 |
 |
Designed to
mount on standard 35mm DIN rails |
|
 |
4 |
|
 |
.05 to 70
amps, 80Vdc |
 |
.050 - 70
amps, 250Vac, 50/60 Hz |
 |
.100 - 50
amps, 80Vdc (VDE) |
 |
.100 - 50
amps, 250Vac, 50/60 Hz (VDE) |
 |
.100 - 30
amps, 415Vac, 50/60 Hz (VDE) |
|
 |
7500 amps, 80
Vdc |
 |
5000 amps,
250Vac, 50/60 Hz |
 |
2000 amps,
277Vac, 50/60 Hz |
 |
2000 amps,
250Vac, 50/60 Hz (VDE) |
 |
2000 amps,
415Vac, 50/60 Hz (VDE) |
 |
4000 amps,
80Vdc (VDE) |
|
 |
UL Recognized |
 |
CSA Certified |
 |
VDE Approved (IELR) |
 |
CE Compliant |
|
View
209/219/229/279
details

|
 |
Front-or-back
connected terminal styles |
 |
E-Frame style
model complies with UL standard 489 |
 |
249 Power
Selector Breaker System is listed as a Branch Circuit Breaker per
UL 489 |
 |
Complies with
International Requirements |
 |
279 style
complies to UL 489A |
|
 |
6 |
|
 |
.100 to 100
amps, 160Vdc |
 |
.100 to 100
amps, 125Vdc |
 |
.100 to 77
amps, 600Vac |
 |
.100 to 100
amps, 120, 240, 277, 480Vac |
 |
.100 to 100
amps, 125Vdc, 240Vac, 240/415Vac (VDE) |
|
 |
5000 amps
|
 |
10000 amps
|
 |
4000 (VDE)
|
|
 |
UL 489 Listed |
 |
UL 489A Listed
(279) |
 |
UL Recognized
|
 |
CSA Certified
|
 |
VDE Approved
|
 |
UL 1500
Certified |
 |
CE Compliant
|
|
View
JAE/JRE/JLE
details
 |
 |
F-Frame style
complies with UL 489 |
 |
Various
terminal options for design flexibility |
 |
Reduced
voltage drop through the circuit breaker compared to other circuit
protective devices |
 |
Auxiliary
switch options |
 |
Mid-trip
handle options |
|
 |
6 |
|
|
UL 489 |
 |
100 - 250
amps, 160Vdc |
 |
100 - 250
amps, 65Vdc |
 |
100-250 amps,
125/250Vdc* |
|
UL 489A
|
 |
275 - 800
amps, 160Vdc** |
 |
275 - 1200
amps, 65Vdc**
* Two poles breaking
** Paralleled poles |
|
 |
10000 amps,
160Vdc |
 |
10000 amps,
125/250Vdc |
 |
50000 amps,
65Vdc |
|
 |
UL 489 Listed |
 |
UL 489A Listed |
 |
UL 1077
Recognized |
 |
CSA Certified |
|
View
AP/UP, AP/MIL
details
 |
 |
QPL to
MIL-PRF-39019 |
 |
Sealed
protection |
 |
Can withstand
100G shock repeatedly |
 |
Tolerates 10G
vibration from 10 to 2000Hz under full load |
 |
Trip point
unaffected by ambient temperatures between -40°C and +100°C |
 |
Ideal for
mobile equipment applications |
|
 |
3 |
|
|
AP Ratings |
 |
.050 to 20
amps, 240Vac, 50 Vdc |
UP Ratings |
 |
.050 to 20
amps, 50Vdc |
| |
.050 to 15
amps, 120Vac |
| |
.050 to 7.5
amps, 240Vac |
|
|
AP Ratings |
 |
500 amps,
50Vdc, 120Vac |
| |
300 amps, 240
Vac |
UP Ratings |
 |
1000 amps,
50Vdc, 240Vac |
|
 |
QPL to
MIL-PRF-39019 |
 |
UL Recognized
(UP style only) |
|
View
APG/UPG/IPG
details

|
 |
Multi-pole
assemblies with single toggle actuation simplifies installation |
 |
QPL to
MIL-PRF-55629 |
 |
Panel seal
toggle version |
 |
Color handles |
 |
Rocker handles |
|
 |
4 |
|
 |
.020 to 30
amps, 277Vac, 65Vdc |
 |
.020 to 50
amps, 250Vac, 65Vdc |
|
 |
2000 amps,
65Vdc |
 |
2100 amps,
250Vac, 400 Hz |
 |
5000 amps,
277Vac, 50/60 Hz |
 |
500 amps, 65
Vdc, 250 Vac (VDE) |
|
 |
UL Recognized |
 |
CSA Certified |
 |
QPL to
MIL-PRF-55629 |
 |
VDE Approved (IPG
only) |
 |
CE Compliant (IPG
only) |
|
View
APL/UPL
details

|
 |
Circuit
protection combines with ON-OFF switching |
 |
Multi-pole
assemblies available with a mix of current ratings, delays and
configurations |
 |
QPL to
MIL-PRF-55629 |
|
 |
9 |
|
 |
.050 to 20
amps, 277Vac |
 |
.050 to 50
amps, 250Vac |
 |
.050 to 100
amps, 65Vdc |
|
 |
5000 amps,
65Vdc (50 amp max. rating) |
 |
5000 amps,
120Vac (50 amp max. rating) |
 |
5000 amps,
277Vac (20 amp max. rating) |
|
 |
UL Recognized |
 |
CSA Certified |
 |
QPL to
MIL-PRF-55629 |
 |
CE Compliant |
|
View
205/295/205D
details
 |
 |
Dust Proof
enclosure |
 |
Tongue and
groove construction provides overlapping closure |
 |
Barrier styles
available for multipole units |
 |
Ideal for
harsh environments |
|
 |
9 |
|
 |
.050 to 30
amps, 277/480Vac |
 |
.050 to 60
amps, 250Vac, 65Vdc |
 |
.050 to 100
amps, 65Vdc |
|
 |
5000 amps,
250Vac, 65Vdc |
 |
3000 amps,
65Vdc |
 |
1500 amps,
277/480Vac (30 amp max.) |
 |
5000 amps,
277/480Vac with 125 amp series fuse |
|
 |
UL Recognized |
 |
CSA Certified |
 |
CE Compliant |
|
View
Protected Battery Disconnect
details
 |
 |
Ideal for
disconnecting system batteries in emergency/maintenance situations |
 |
Disconnect and
over current protection |
 |
Completely
front accessible enclosure |
 |
Manual and
remote disconnect capability |
 |
Wall, rack or
battery stand mounting |
 |
Optional LED
indication of power on, off and/or tripped condition |
 |
Optional alarm
circuit |
|
 |
6 |
|
|
JPBD
Ratings |
 |
1000 to 1200
amps, 65Vdc |
 |
400 to 800
amps, 160Vdc |
| |
|
|
LPBD
Ratings |
 |
50 to 100
amps, 80Vdc |
 |
125 to 200
amps, 65Vdc |
|
|
JPBD
Ratings |
 |
50000 amps,
65Vdc |
 |
10000 amps,
160Vdc |
| |
|
|
LPBD
Ratings |
 |
50000 amps,
80Vdc |
 |
50000 amps,
65Vdc |
|
 |
UL Listed
under
UL file E220375 (JPBD only) |
|
| *Consult factory for
conditions of acceptability. |